MOXA NPort 5600-8-DT Desktop Series
Compact 8-port Serial Device Servers
- 8 serial ports supporting RS-232/422/485
- Compact desktop design
- 10/100M auto-sensing Ethernet
- Built-in 15 KV ESD protection for all serial signals
- Easy IP address configuration with LCD panel
- Choice of configuration methods: Web console, Telnet console, and Windows utility
- Versatile socket operation modes, including TCP Server, TCP Client, UDP, and Real COM
- SNMP MIB-II for network management
- Supports Moxa´s MXview industrial network management software via the MXview Plug-in
NPort® 5600-8-DT-Geräteserver können komfortabel und transparent acht serielle Geräte mit einem Ethernet verbinden, sodass Sie Ihre seriellen Geräte mit einer einfachen Basiskonfiguration vernetzen können. Sie können das Management Ihrer seriellen Geräte zentralisieren und Managementserver über das Netzwerk verteilen. Da die NPort® 5600-8-DT-Geräteserver im Vergleich zu unseren 19´´ Modellen einen kleineren Formfaktor aufweisen, sind sie eine gute Wahl für Anwendungen, die weitere serielle Ports benötigen, ohne dass Montageschienen zur Verfügung stehen.
Convenient Design for RS-485 Applications
The NPort® 5650-8-DT device servers support selectable 1K-ohm and 150K-ohm pull high/low resistors and a 120-ohm terminator. In some critical environments, termination resistors may be needed to prevent the reflection of serial signals. When using termination resistors, it is also important to set the pull high/low resistors correctly so that the electrical signal is not corrupted. Since no set of resistor values is universally compatible with all environments, NPort® 5600-8-DT device servers use DIP switches to allow users to adjust termination and pull high/low resistor values manually for each serial port.
Convenient Power Inputs
The NPort® 5650-8-DT device servers support both a power terminal block and power jack for ease of use and greater flexibility. Users can connect the terminal block directly to a DC power source, or use the power jack to connect to an AC circuit through an adaptor.
LED Indicators to Ease Your Maintenance Tasks
The System LED, Serial Tx/Rx LEDs, and Ethernet LEDs (located on the RJ45 connector) provide a great tool for basic maintenance tasks and help engineers analyze problems in the field. The NPort® 5600’s LEDs not only indicate current system and network status, but also help field engineers monitor the status of attached serial devices.
Two Ethernet Ports for Convenient Cascade-style Wiring
The NPort® 5600-8-DT device servers come with two Ethernet ports that can be used as Ethernet switch ports. Connect one port to the network or server, and the other port to another Ethernet device. The dual Ethernet ports eliminate the need to connect each device to a separate Ethernet switch, reducing wiring costs.
Automatic Warning Function by Speaker and/or E-mail
The built-in speakers can be used to alert administrators of problems with the Ethernet links or power input. The web console indicates which Ethernet link or power input has failed. An e-mail warning can also be issued when an exception is detected. These functions are valuable tools that enable maintenance engineers to react promptly to emergency situations.
Ethernet Interface
Number of Ports
2 (1 IP)
Speed
10/100 Mbps, auto MDI/MDIX
Connector
8-pin RJ45
Magnetic Isolation Protection
1.5 KV built-in
Serial Interface
Number of Ports
8
Serial Standards
NPort 5610-8-DT: RS-232
NPort 5650-8-DT: RS-232/422/485
Connector
NPort 5610-8-DT/5650-8-DT/5650I-8-DT: DB9 male
NPort 5610-8-DT-J/5650-8-DT-J: RJ45 (8 pins)
Serial Line Protection
15 KV ESD protection for all signals
2 KV isolation protection (NPort 5650I-8-DT only)
RS-485 Data Direction Control
ADDC® (automatic data direction control)
Pull High/Low Resistor for RS-485
1 KΩ, 150 KΩ
Terminator for RS-485
120 Ω
Serial Communication Parameters
Data Bits
5, 6, 7, 8
Stop Bits
1, 1.5, 2
Parity
None, Even, Odd, Space, Mark
Flow Control
DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
Baudrate
50 bps to 921.6 Kbps
Serial Signals
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
Data+, Data-, GND
Software
Network Protocols
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1, HTTP, SMTP, SNTP, Rtelnet, ARP, RFC2217
Configuration Options
Web Console, Telnet Console, Serial Console, Windows Utility
Windows RealCOM Drivers
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8 x86/x64, 2012 x64, Embedded CE 5.0/6.0, XP Embedded
Fixed TTY Drivers
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i
Linux Real TTY Drivers
Linux kernel 2.4.x, 2.6.x, 3.x
Mini Screen with Push Buttons
LCD Panel
Liquid Crystal Display on the case
Push Buttons
Four push buttons for convenient on-site configuration
Physical Characteristics
Housing
Metal, IP30 protection
Weight
NPort 5610-8-DT: 1760 g
NPort 5610-8-DT-J: 1710 g
NPort 5650-8-DT: 1770 g
NPort 5650-8-DT-J: 1710 g
NPort 5650I-8-DT: 1850 g
Dimensions Without ears: 197 x 44 x 125 mm (7.76 x 1.73 x 4.92 in)
With ears: 229 x 46 x 125 mm (9.01 x 1.81 x 4.92 in)
With DIN-Rail kit on bottom panel: 197 x 53 x 125 mm (7.76 x 2.09 x 4.92 in)
Environmental Limits
Operating Temperature
0 to 55°C (32 to 131°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Power Requirements
Input Voltage
12 to 48 VDC
Power Consumption
NPort 5610-8-DT:
611 mA @ 12 V, 300 mA @ 24 V, 140 mA @ 48 V
NPort 5610-8-DT-J:
611 mA @ 12 V, 300 mA @ 24 V, 140 mA @ 48 V
NPort 5650-8-DT:
615 mA @ 12 V, 300 mA @ 24 V, 156 mA @ 48 V
NPort 5650I-8-DT:
1066 mA @ 12 V, 510 mA @ 24 V, 200 mA @ 48 V
NPort 5650-8-DT-J:
615 mA @ 12 V, 300 mA @ 24 V, 156 mA @ 48 V
Standards and Certifications
Safety
UL 60950-1, EN 60950-1
EMC
CE, FCC
EMI
EN 55022 Class A, FCC Part 15 Subpart B Class A
EMS
EN 55024
Reliability
Alert Tools
Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger
Built-in WDT (watchdog timer)
MTBF (mean time between failures)
163,356 hrs
The NPort® 5650-8-DT device servers support selectable 1K-ohm and 150K-ohm pull high/low resistors and a 120-ohm terminator. In some critical environments, termination resistors may be needed to prevent the reflection of serial signals. When using termination resistors, it is also important to set the pull high/low resistors correctly so that the electrical signal is not corrupted. Since no set of resistor values is universally compatible with all environments, NPort® 5600-8-DT device servers use DIP switches to allow users to adjust termination and pull high/low resistor values manually for each serial port.
Convenient Power Inputs
The NPort® 5650-8-DT device servers support both a power terminal block and power jack for ease of use and greater flexibility. Users can connect the terminal block directly to a DC power source, or use the power jack to connect to an AC circuit through an adaptor.
LED Indicators to Ease Your Maintenance Tasks
The System LED, Serial Tx/Rx LEDs, and Ethernet LEDs (located on the RJ45 connector) provide a great tool for basic maintenance tasks and help engineers analyze problems in the field. The NPort® 5600’s LEDs not only indicate current system and network status, but also help field engineers monitor the status of attached serial devices.
Two Ethernet Ports for Convenient Cascade-style Wiring
The NPort® 5600-8-DT device servers come with two Ethernet ports that can be used as Ethernet switch ports. Connect one port to the network or server, and the other port to another Ethernet device. The dual Ethernet ports eliminate the need to connect each device to a separate Ethernet switch, reducing wiring costs.
Automatic Warning Function by Speaker and/or E-mail
The built-in speakers can be used to alert administrators of problems with the Ethernet links or power input. The web console indicates which Ethernet link or power input has failed. An e-mail warning can also be issued when an exception is detected. These functions are valuable tools that enable maintenance engineers to react promptly to emergency situations.
Ethernet Interface
Number of Ports
2 (1 IP)
Speed
10/100 Mbps, auto MDI/MDIX
Connector
8-pin RJ45
Magnetic Isolation Protection
1.5 KV built-in
Serial Interface
Number of Ports
8
Serial Standards
NPort 5610-8-DT: RS-232
NPort 5650-8-DT: RS-232/422/485
Connector
NPort 5610-8-DT/5650-8-DT/5650I-8-DT: DB9 male
NPort 5610-8-DT-J/5650-8-DT-J: RJ45 (8 pins)
Serial Line Protection
15 KV ESD protection for all signals
2 KV isolation protection (NPort 5650I-8-DT only)
RS-485 Data Direction Control
ADDC® (automatic data direction control)
Pull High/Low Resistor for RS-485
1 KΩ, 150 KΩ
Terminator for RS-485
120 Ω
Serial Communication Parameters
Data Bits
5, 6, 7, 8
Stop Bits
1, 1.5, 2
Parity
None, Even, Odd, Space, Mark
Flow Control
DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
Baudrate
50 bps to 921.6 Kbps
Serial Signals
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
Data+, Data-, GND
Software
Network Protocols
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1, HTTP, SMTP, SNTP, Rtelnet, ARP, RFC2217
Configuration Options
Web Console, Telnet Console, Serial Console, Windows Utility
Windows RealCOM Drivers
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8 x86/x64, 2012 x64, Embedded CE 5.0/6.0, XP Embedded
Fixed TTY Drivers
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i
Linux Real TTY Drivers
Linux kernel 2.4.x, 2.6.x, 3.x
Mini Screen with Push Buttons
LCD Panel
Liquid Crystal Display on the case
Push Buttons
Four push buttons for convenient on-site configuration
Physical Characteristics
Housing
Metal, IP30 protection
Weight
NPort 5610-8-DT: 1760 g
NPort 5610-8-DT-J: 1710 g
NPort 5650-8-DT: 1770 g
NPort 5650-8-DT-J: 1710 g
NPort 5650I-8-DT: 1850 g
Dimensions Without ears: 197 x 44 x 125 mm (7.76 x 1.73 x 4.92 in)
With ears: 229 x 46 x 125 mm (9.01 x 1.81 x 4.92 in)
With DIN-Rail kit on bottom panel: 197 x 53 x 125 mm (7.76 x 2.09 x 4.92 in)
Environmental Limits
Operating Temperature
0 to 55°C (32 to 131°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Power Requirements
Input Voltage
12 to 48 VDC
Power Consumption
NPort 5610-8-DT:
611 mA @ 12 V, 300 mA @ 24 V, 140 mA @ 48 V
NPort 5610-8-DT-J:
611 mA @ 12 V, 300 mA @ 24 V, 140 mA @ 48 V
NPort 5650-8-DT:
615 mA @ 12 V, 300 mA @ 24 V, 156 mA @ 48 V
NPort 5650I-8-DT:
1066 mA @ 12 V, 510 mA @ 24 V, 200 mA @ 48 V
NPort 5650-8-DT-J:
615 mA @ 12 V, 300 mA @ 24 V, 156 mA @ 48 V
Standards and Certifications
Safety
UL 60950-1, EN 60950-1
EMC
CE, FCC
EMI
EN 55022 Class A, FCC Part 15 Subpart B Class A
EMS
EN 55024
Reliability
Alert Tools
Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger
Built-in WDT (watchdog timer)
MTBF (mean time between failures)
163,356 hrs
Ordering Information | |
NPort 5610-8-DT | 8-port RS-232 serial device server, DB9 connectors, desktop model |
NPort5610-8-DT-J | 8-port RS-232 serial device server, RJ45 connectors, desktop model |
NPort 5650-8-DT | 8-port RS-232/422/485 serial device server, 12 to 48 VCD power input, desktop model |
NPort 5650I-8-DT | NPort 5650-8-DT with 2 KV isolation |
NPort 5650-8-DT-J | 8-port RS-232/422/485 serial device server, RJ45 connectors, desktop model |
Above items include: |
|
Optional Accessories | |
DK-35A | DIN-Rail Mounting Kit (35 mm) |
CBL-RJ45M9-150 | RJ45 8-pin to DB9 Male cable, 150 cm |
CBL-RJ45F9-150 | RJ45 8-pin to DB9 Female cable, 150 cm |
CBL-RJ45M25-150 | RJ45 8-pin to DB25 Male cable, 150 cm |
CBL-RJ45F25-150 | RJ45 8-pin to DB25 Female cable, 150 cm |
NP21101 | DB25(M) to DB9(F) RS-232 cable, 30 cm |
Kunden, die diesen Artikel gesehen haben, sahen auch